Features Low price and high reliability 170V-264V AC input power High efficiency and low operation temperature Soft-start current can reduce the AC input impact effectively With Short-circuit and overload protection 100% full-load burning test Small bulk design Installed with EMI filter, minimum wave. 2 years warranty |
|||||
|
|
||||
|
|||||
|
|||||
Model |
HS-25-5 |
HS-25-12 |
HS-25-15 |
HS-25-24 |
DC output voltage |
5V |
12V |
15V |
24V |
Output voltage error(Note:2) |
±2% |
±1% |
±1% |
±1% |
Rated output current |
5A |
2.1A |
1.7A |
1.1A |
Output current rage |
0-5A |
0-2.1A |
0-1.7A |
0-1.1A |
Wave and noise(Note :3) |
50mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Inlet stability(Note :4) |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability (Note :5) |
±1% |
±0.5% |
±0.5% |
±0.5% |
DC output power |
25W |
25.2W |
25.5W |
26.4W |
Efficiency |
72% |
76% |
77% |
80%/ |
Adjustable range for DC voltage |
+10,-5% |
+10% |
+10% |
+10% |
AC input voltage range |
170-264VAC,47-63Hz;240~370VDC |
|||
Input current |
0.35A/230A |
|||
AC Inrush current |
Cold-start current 30A/230V |
|||
Leakage current |
<0.5mA/240VAC |
|||
Overload protection |
105%-150%Type:Foldback:current limiting reset: auto recovery |
|||
Temperature coefficient |
±0.03%/℃(0-50℃) |
|||
Setup rise hold up time |
200ms,100ms,30ms/230VAC |
|||
Vibration |
10-500Hz,2G 10min,/1cycle,Period for60min,Each axes |
|||
Withstand voltage |
Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC |
|||
Isolation resistance |
Input and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ |
|||
Working temperature and humidity |
-10℃~+60℃(Refer to output derating curve),20%~90%RH |
|||
Store temperature and humidity |
-20℃~+85℃。10%~95%RH |
|||
Overall dimension |
84×58×38mm |
|||
Weight |
0.16Kgs |
|||
Note: |